Showing 97–112 of 253 results
-

IIW TYPE 2 UT (IMPERIAL) CALIBRATION BLOCK
Manufactured in accordance with the specifications of the International Institute of Welding, ASTM E164 and U.S. Air Force NDI Manual T.O. 33B-1-1, the IIW-Type 2 (IIW-Type 1 modified version) is used for the purposes described below:
- Calibration of sensitivity, distance, resolution, and horizontal linearity on Straight Beam Transducers.
- Calibration of beam index, sound path angle, distance time base and distance sensitivity curve on angle beam transducers.
Features
- Dimensions 4″ (height) X 12″ (length) X 1″ (width)
- Weight 11,288 LBS
- Material 1018 STEEL, NICKEL PLATED
- Specifications ASTM E 164 FIG. A1.1. and TM 1-1500-335-23
-

IIW TYPE 2 UT (IMPERIAL) CALIBRATION BLOCK
Manufactured in accordance with the specifications of the International Institute of Welding, ASTM E164 and U.S. Air Force NDI Manual T.O. 33B-1-1, the IIW-Type 2 (IIW-Type 1 modified version) is used for the purposes described below:
- Calibration of sensitivity, distance, resolution, and horizontal linearity on Straight Beam Transducers.
- Calibration of beam index, sound path angle, distance time base and distance sensitivity curve on angle beam transducers.
Features
- Dimensions: 4″ (height) X 12″ (length) X 1″ (width)
- Weight: 11,473 LBS
- Material: 304 STAINLESS STEEL
- Specifications: ASTM E 164 FIG. A1.1. & TM 1-1500-335-23
-

IIW TYPE 2 UT (IMPERIAL) CALIBRATION BLOCK
Manufactured in accordance with the specifications of the International Institute of Welding, ASTM E164 and U.S. Air Force NDI Manual T.O. 33B-1-1, the IIW-Type 2 (IIW-Type 1 modified version) is used for the purposes described below:
– Calibration of sensitivity, distance, resolution, and horizontal linearity on.
Straight beam transducers.
– Calibration of beam index, sound path angle, distance time base and distance sensitivity curve on angle beam transducers.
Features
- Dimensions: 4″ (height) X 12″ (length) X 1″ (width)
- Weight: 4,110 LBS
- Material: 7075-T6 ALUMINIUM
- Specifications: ASTM E 164 FIG. A1.1. & TM 1-1500-335-23
-

IIW TYPE 2 UT CALIBRATION BLOCK (METRIC)
Manufactured in accordance with the specifications of the International Institute of Welding, ASTM E164 and U.S. Air Force NDI Manual T.O. 33B-1-1, the IIW-Type 2 (IIW-Type 1 modified version) (Metric Version) is used for the purposes described below:
Calibration of sensitivity, distance, resolution and horizontal linearity on Straight Beam Transducers.
Calibration of beam index, sound path angle, distance time base and distance sensitivity curve on angle beam transducers.
Features
- Dimensions 3.937″ (height) X 11.811″ (length) X 0.984″ (width)
- Weight 10.856 LBS
- Material 1018 STEEL, NICKEL PLATED
- Specifications ASTM E 164 FIG. A1.1. & TM 1-1500-335-23
-

IIW TYPE 2 UT CALIBRATION BLOCK (METRIC)
Manufactured in accordance with the specifications of the International Institute of Welding, ASTM E164 and U.S. Air Force NDI Manual T.O. 33B-1-1, the IIW-Type 2 (IIW-Type 1 modified version) (Metric Version) is used for the purposes described below:
Calibration of sensitivity, distance, resolution and horizontal linearity on Straight Beam Transducers.
Calibration of beam index, sound path angle, distance time base and distance sensitivity curve on angle beam transducers.
Features
- Dimensions: 3.937″ (H) X 11.811″ (L) X 0.984″ (W)
- Weight: 11.034 LBS
- Material: 304 STAINLESS STEEL
- Specifications: ASTM E 164 FIG. A1.1. & TM 1-1500-335-23
-

IIW TYPE 2 UT CALIBRATION BLOCK (METRIC)
Manufactured in accordance with the specifications of the International Institute of Welding, ASTM E164 and U.S. Air Force NDI Manual T.O. 33B-1-1, the IIW-Type 2 (IIW-Type 1 modified version) (Metric Version) is used for the purposes described below:
Calibration of sensitivity, distance, resolution and horizontal linearity on straight beam transducers.
Calibration of beam index, sound path angle, distance time base and distance sensitivity curve on angle beam transducers.
Features:
- Dimensions: 3.937″ (H) X 11.811″ (L) X 0.984″ (W).
- Weight: 3.952 LBS
- Material: 7075-T6 ALUMINUM
- Specifications: ASTM E 164 FIG. A1.1. & TM 1-1500-335-23
-

CALIBRATION BLOCK NO. 1 (K1)
Used to calibrate ultrasonic flaw detection equipment both in laboratory and on-site conditions. Manufactured in accordance with EN 12223 and ISO 2400.
Features:
- Dimensions: 3.937″ (H) X 11.811″ (L) X 0.984″ (W)
- Weight: 11.232 LBS
- Material: 1018 STEEL, NICKEL PLATED
- Specifications: EN 12223 & ISO 2400
-

CALIBRATION BLOCK NO. 1 (K1)
Used to calibrate ultrasonic flaw detection equipment both under laboratory and on-site conditions. Manufactured in accordance with EN 12223 and ISO 2400.
Features:
- Dimensions: 3.937″ (H) X 11.811″ (L) X 0.984″ (W)
- Weight: 11.415 LBS
- Material1: 304 STAINLESS STEEL.
- Specifications: EN 12223 & ISO 2400
-

CALIBRATION BLOCK NO. 1 (K1)
Used to calibrate ultrasonic flaw detection equipment both under laboratory and on-site conditions. Manufactured in accordance with EN 12223 and ISO 2400.
Features:
- Dimensions: 3.937″ (H) X 11.811″ (L) X 0.984″ (W)
- Weight: 4.086 LBS
- Material: 7075-T6 ALUMINIUM
- Specifications: EN 12223 & ISO 2400
-

NO. 1 (K1) CALIBRATION BLOCK (WITH CIRCULAR REFLECTOR)
Used to calibrate ultrasonic flaw detection equipment both in laboratory and on-site conditions. Manufactured in accordance with EN 12223 and ISO 2400. The block includes a circular reflector.
Features:
- Dimensions: 3.937″ (H) X 11.811″ (L) X 0.984″ (W)
- Weight: 11.225 LBS
- Material: 1018 STEEL, NICKEL PLATED
- Specifications: EN 12223 & ISO 2400
-

NO. 1 (K1) CALIBRATION BLOCK (WITH CIRCULAR REFLECTOR)
Used to calibrate ultrasonic flaw detection equipment both in laboratory and on-site conditions. Manufactured in accordance with EN 12223 and ISO 2400. The block includes a circular reflector.
Features:
- Dimensions: 3.937″ (H) X 11.811″ (L) X 0.984″ (W).
- Weight: 11.409 LBS
- Material: STAINLESS STEEL 304
- Specifications: EN 12223 & ISO 2400
-

NO. 1 (K1) CALIBRATION BLOCK (WITH CIRCULAR REFLECTOR)
Used to calibrate ultrasonic flaw detection equipment both in laboratory and on-site conditions. Manufactured in accordance with EN 12223 and ISO 2400. The block includes a circular reflector of 25 mm radius, 3 mm depth and 3 mm width.
Features:
Dimensions: 3.937″ (H) X 11.811″ (L) X 0.984″ (W).
Weight: 4.084 LBS
Material: 7075-T6 ALUMINIUM
Specifications: EN 12223 & ISO 2400
-

NO. 1 (K1) CALIBRATION BLOCK (WITH SLOTS)
Used to calibrate ultrasonic flaw detection equipment both in laboratory and on-site conditions. Manufactured in accordance with EN 12223 and ISO 2400. The block includes 2 slots 30 mm long, 4 mm deep and 0.5 mm wide.
Features:
- Dimensions: 3.937″ (H) X 11.811″ (L) X 0.984″ (W).
- Weight: 11.230 LBS
- Material: 1018 STEEL, NICKEL PLATED
- Specifications: EN 12223 & ISO 2400
-

NO. 1 (K1) CALIBRATION BLOCK (WITH SLOTS)
Used to calibrate ultrasonic flaw detection equipment both in laboratory and on-site conditions. Manufactured in accordance with EN 12223 and ISO 2400. The block includes 2 slots 30 mm long, 4 mm deep and 0.5 mm wide.
Features:
- Dimensions: 3.937″ (H) X 11.811″ (L) X 0.984″ (W).
- Weight: 11.413 LBS
- Material: 304 STAINLESS STEEL
- Specifications: EN 12223 & ISO 2400
-

NO. 1 (K1) CALIBRATION BLOCK (WITH SLOTS)
Used to calibrate ultrasonic flaw detection equipment both in laboratory and on-site conditions. Manufactured in accordance with EN 12223 and ISO 2400. The block includes 2 slots 30 mm long, 4 mm deep and 0.5 mm wide.
Features:
Dimensions: 3.937″ (H) X 11.811″ (L) X 0.984″ (W).
Weight: 4.086 LBS
Material: 7075-T6 ALUMINIUM
Specifications: EN 12223 & ISO 2400
-

CALIBRATION BLOCK No. 2 (K2) (12.5 mm THICK)
Used for on-site checking of index, time base, beam angle and gain of miniature shear wave probe. Manufactured in accordance with EN 27963, DIN 54-120 and ISO 7963. 12.5 mm thickness.
Features:
- Dimensions: 1.705″ (H) X 2.953″ (L) X 0.492″ (W).
- Weight: 0.468 LBS
- Material: 1018 STEEL, NICKEL PLATED
- Specifications: EN 27963, DIN 54-120 & ISO 7963