Non-Destructive Testing (NDT)

  • PA-2491-1018

    PA-2491-1018

    E2491 PHASED ARRAY CALIBRATION BLOCK (IMPERIAL)

    Used to determine long-term instrument performance changes, generate DAC curves and evaluate linear/angular resolution. This reference block focuses on beam steering capability and capacity. Manufactured in accordance with ASTM E2491.


    Features:

    • Dimensions: 4″ (height) X 6″ (length) X 1″ (width).
    • Weight: 6,773 LBS
    • Material: 1018 STEEL, NICKEL PLATED
    • Specifications: ASTM E2491
  • PA-2491-304

    PA-2491-304

    E2491 PHASED ARRAY CALIBRATION BLOCK (IMPERIAL)

    Used to determine long-term instrument performance changes, generate DAC curves and evaluate linear/angular resolution. This reference block focuses on beam steering capability and capacity. Manufactured in accordance with ASTM E2491.


    Features:

    • Dimensions: 4″ (height) X 6″ (length) X 1″ (width).
    • Weight: 6,885 LBS
    • Material: STAINLESS STEEL 304
    • Specifications: ASTM E2491
  • PA-2491-7075

    PA-2491-7075

    E2491 PHASED ARRAY CALIBRATION BLOCK (IMPERIAL)

    Used to determine long-term instrument performance changes, generate DAC curves and evaluate linear/angular resolution. This reference block focuses on beam steering capability and capacity. Manufactured in accordance with ASTM E2491.


    Features:

    • Dimensions: 4″ (height) X 6″ (length) X 1″ (width).
    • Weight: 2,418 LBS
    • Material: 7075-T6 ALUMINIUM
    • Specifications: ASTM E2491
  • PA-2491-M-1018

    PA-2491-M-1018

    E2491 PHASED ARRAY CALIBRATION BLOCK (METRIC)

    Used to determine long-term instrument performance changes, generate DAC curves and evaluate linear/angular resolution. This reference block (metric version) focuses on beam steering capability and capacity. Manufactured in accordance with ASTM E2491.


    Features:

    • Dimensions: 3.937″ (H) X 5.906″ (L) X 0.984″ (W).
    • Weight: 6.459 LBS
    • Material: 1018 STEEL, NICKEL PLATED
    • Specifications: ASTM E2491
  • PA-2491-M-304

    PA-2491-M-304

    E2491 PHASED ARRAY CALIBRATION BLOCK (METRIC)

    Used to determine long-term instrument performance changes, generate DAC curves and evaluate linear/angular resolution. This reference block (metric version) focuses on beam capacity and beam direction. Manufactured in accordance with ASTM E2491.


    Features:

    • Dimensions: 3.937″ (H) X 5.906″ (L) X 0.984″ (W).
    • Weight: 6.565 LBS
    • Material: 304 STAINLESS STEEL
    • Specifications: ASTM E2491
  • PA-2491-M-7075

    PA-2491-M-7075

    E2491 PHASED ARRAY CALIBRATION BLOCK (METRIC)

    Used to determine long-term instrument performance changes, generate DAC curves and evaluate linear/angular resolution. This reference block (metric version) focuses on beam capacity and beam direction. Manufactured in accordance with ASTM E2491.


    Features:

    • Dimensions: 3.937″ (H) X 5.906″ (L) X 0.984″ (W).
    • Weight: 2.306 LBS
    • Material: 7075-T6 ALUMINIUM
    • Specifications: ASTM E2491
  • PA-IIW-1018

    PA-IIW-1018

    PHASED ARRAY CALIBRATION BLOCK TYPE A (IMPERIAL)

    The Phased Array Type A block has the following Phased Array applications described:

    Beam angle verification.
    Sensitivity calibration.
    Wedge delay calibration.
    DAC/TCG and more.


    Features:

    • Dimensions: 4″ (height) X 12″ (length) X 1″ (width).
    • Weight: 12,072 LBS
    • Material: 1018 STEEL, NICKEL PLATED
    • Specifications: ASTM E 164 FIG. A1.1
  • PA-IIW-304

    PA-IIW-304

  • PA-IIW-7075

    PA-IIW-7075

    PHASED ARRAY CALIBRATION BLOCK TYPE A (IMPERIAL)

    The Phased Array Type A block has the following Phased Array applications described:

    Beam angle verification.
    Sensitivity calibration.
    Wedge delay calibration.
    DAC/TCG and more.


    Features:

    • Dimensions: 4″ (height) X 12″ (length) X 1″ (width).
    • Weight: 4,310 LBS
    • Material: 7075-T6 ALUMINUM
    • Specifications: ASTM E 164 FIG. A1.1
  • PA-IIW-M-1018

    PA-IIW-M-1018

    PHASED ARRAY CALIBRATION BLOCK TYPE A (METRIC VERSION)

    The Phased Array block type A (metric version) has the following Phased Array applications described:

    Beam angle verification.
    Sensitivity calibration.
    Wedge delay calibration.
    DAC/TCG and more.


    Features:

    • Dimensions: 3.937″ (H) X 11.811″ (L) X 0.984″ (W).
    • Weight: 11.701 LBS
    • Material: 1018 STEEL, NICKEL PLATED
    • Specifications: ASTM E 164 FIG. A1.1
  • PA-IIW-M-304

    PA-IIW-M-304

    PHASED ARRAY CALIBRATION BLOCK TYPE A (METRIC VERSION)

    The Phased Array block type A (metric version) has the following Phased Array applications described:

    Beam angle verification.
    Sensitivity calibration.
    Wedge delay calibration.
    DAC/TCG and more.


    Features:

    • Dimensions: 3.937″ (H) X 11.811″ (L) X 0.984″ (W).
    • Weight: 11.894 LBS
    • Material: 304 STAINLESS STEEL
    • Specifications: ASTM E 164 FIG. A1.1
  • PA-IIW-M-7075

    PA-IIW-M-7075

    PHASED ARRAY CALIBRATION BLOCK TYPE A (METRIC VERSION)

    The Phased Array block type A (metric version) has the following Phased Array applications described:

    Beam angle verification.
    Sensitivity calibration.
    Wedge delay calibration.
    DAC/TCG and more.


    Features:

    • Dimensions: 3.937″ (H) X 11.811″ (L) X 0.984″ (W).
    • Weight: 4.178 LBS
    • Material: 7075-T6 ALUMINIUM
    • Specifications: ASTM E 164 FIG. A1.1
  • PALM Flat Scanner

    PALM Flat Scanner

    A versatile and ergonomic UT inspection tool

    The PALM Flat Scanner (PALM Flat Scanner), part of the PALM scanner family, is a versatile and ergonomic UT inspection tool that features an integrated encoder and magnetic wheels to allow vertical and overhead use. The scanner can be used on diameters greater than 90 mm for circumferential scanning and 200 mm for axial scanning.

  • PALM Scanner

    PALM Scanner

    Máquina de ultrasonido portátil de mano

     
    Evaluación de soldadura de tuberías de pequeño diámetro y difícil acceso.
     
    La familia de escáneres PALM inspecciona tuberías con diámetros desde 1,5” hasta 3,5”. Las herramientas se pueden adaptar con varias cuñas y sondas de matriz en fase para adaptarse a cualquier procedimiento de inspección independientemente del espesor del tubo, el material o los criterios de aceptación.

  • Película Radiográfica AGFA

    Película Radiográfica AGFA

    AGFA’s radiographic film is a reliable and high quality solution for industrial radiography applications. With a combination of benefits, key features and advantages, this film guarantees accurate and detailed results in defect detection and quality control.

  • Penetrant Testing Applicators

    Penetrant Testing Applicators

    Portable Pressure Sprayer and Water Spray Gun

    These product applicators and water sprayers will help you speed up your penetrant inspection process by offering fast, consistent and even application of product or water to the part surface. Manufactured from high-quality materials and components, this water sprayer and portable pressure sprayer will deliver years of trouble free performance under all usage situations and in a variety of liquid penetrant testing applications.